# Infor LN 'unable to create a session': causes and how to fix it

> Source: https://netray.co/erp-help/infor-ln-unable-to-create-a-session-fix
> Publisher: Netray (netray.co), AI and integration engineering for ERP and manufacturing systems.
> Section: ERP Help

## Short answer

This message means the client reached LN but the server could not start the session process (a bshell) or could not load the session. Work from the server side: check the bshell log, licence and user limits, the user's authorizations, and whether the session or its dependent objects exist and are compiled.

## Kind

error

## System

infor-ln

## Erp

Infor LN

## Module

Infrastructure / bshell

## Query

infor unable to create a session

## Alternate Queries

- infor ln unable to create session bshell
- infor ln cannot start session
- infor ln studio unable to create session

## Applies To

Infor LN 10.x on-prem and private cloud, LN UI, Web UI and LN Studio.

## Steps

### Diagnose in this order

**Items:**

- Note whether it fails for one session, one user, or everybody. Everybody points to infrastructure, one user to authorization or licence, one session to the object.
- Check the bshell logs on the application server (under the BSE log directory) for the time of the failure. A start-up error is usually printed there.
- Confirm the bshell can actually spawn: free disk space and memory on the application server, temp directory writable, and process limits for the OS account.
- Verify the user is within licence and concurrent session limits and that the license manager is reachable.
- Verify the user's authorization for the session (session authorizations and the user template).
- Open the session code in Studio or the session definition session and confirm it exists, is in the right package VRC and has a compiled object.
- Retry from a different client (LN UI versus Studio) to separate client problems from server problems.

## Sections

### Infrastructure causes

**Body:**

If many users fail at once, the usual suspects are exhausted process resources, a full BSE temp or log volume, a stopped or unreachable license manager, or a bshell server that was restarted without its dependent services. Windows application servers may also hit desktop heap or service account permission problems.

A change window earlier that day is the best clue. Look for OS patching, a changed service account, or a moved BSE path. The bshell log records the failing start-up step more reliably than the client dialog does.

### User and licence causes

**Body:**

Per-user failures usually trace to an expired or locked user, a missing authorization, or hitting the licensed concurrent user ceiling. LN will not always say 'licence' in the client message, so confirm in the licence usage view before changing anything else.

See the related page on 'not authorized to run session' for the authorization path. Copying a working colleague's user template is the fastest way to confirm an authorization cause.

### Object causes

**Body:**

A single session failing after a deployment often means a missing or uncompiled object, a wrong package VRC for the user's package combination, or a script that errors in its start-up section. Recompile the session and its libraries, then retest.

For custom sessions built in Studio, check that the session was converted to runtime and that the customization is in the VRC the user's package combination resolves to.

## Pitfalls

- Restarting the application server before capturing the bshell log, which destroys the evidence.
- Treating a licence issue as an authorization issue and editing roles unnecessarily.
- Recompiling objects in production without a change record.
- Assuming the client dialog text is the real root cause.
- Ignoring disk space on the BSE log and temp volumes.

## Ai Angle

An on-prem assistant given read access to bshell logs and the LN authorization tables can triage this: it matches the timestamp to the log line, checks whether the user and session authorizations exist, and gives the admin a ranked list of causes. It does not change anything. Netray builds this as a private retrieval layer, so logs never leave your network.

## Faq

### Where are the LN bshell logs?

**Answer:** They sit under the BSE directory on the application server, in the log folder, with names that start with log.bshell. The exact path depends on your installation, so check the BSE environment variable of the service account that runs LN.

### Does this error mean a licence problem?

**Answer:** Sometimes. If all users fail after a threshold of concurrent sessions, check licence usage. Otherwise the cause is more often server resources or an object problem. Do not assume.

### Why does it only fail in Studio?

**Answer:** Studio opens sessions for development and needs developer authorizations and the right VRC. A user who can run a session may not be able to open it in Studio.

### Will recompiling fix it?

**Answer:** Only if the cause is a missing or stale object. Confirm from the log before recompiling.

## Search terms

infor unable to create a session, infor ln unable to create session, infor ln bshell, infor ln cannot start session, infor ln studio session error, infor ln license session limit, infor ln log bshell, infor ln session not starting

---
Talk to an engineer: https://netray.co/contact?intent=erp_ai | Machine catalog: https://netray.co/agent/catalog.json