Gage Resolution and Number of Distinct Categories Calculator
Two quick checks catch many weak measurement systems: is the gage resolution fine enough for the tolerance, and can the system tell parts apart. This calculator does both from numbers you already have.
Your numbers
Total width of the tolerance band.
Display increment or least count.
From your gage R&R study.
From your gage R&R study.
Your results
Rules of thumb from common MSA guidance. Your customer or standard may set different limits. Use the same units for all inputs.
Review your measurement system strategy
Optional conversation about connecting gage and inspection data to your ERP.
Optional. The tool and every export work without this. No spam.
How to use it
Enter the total tolerance and the smallest increment your gage can display. The calculator shows the ratio of tolerance to resolution and the resolution that would satisfy a 10 to 1 rule. For the second check, enter the part variation and the gage R&R standard deviation from your study, and read the number of distinct categories.
- Use the same units everywhere
- Resolution means the display increment, not the accuracy
- Use standard deviations, not study variation multiples, for PV and GRR
The formulas
The resolution check is tolerance divided by resolution, with 10 or more considered adequate. The number of distinct categories is 1.41 times PV divided by GRR, rounded down, following common AIAG MSA practice. A value of 5 or more suggests the system can distinguish parts well enough for process control, while below 2 means it is little better than a pass-fail call.
Reading the result
If the ratio is below 10, consider a gage with finer resolution, but note that a finer display does not fix poor repeatability. If ndc is low, look at the sources of variation in the gage R&R study, such as appraiser technique, fixturing or part form, before buying new equipment. Document the decision in your MSA plan.
Frequently Asked Questions
Why 10 to 1?
It is a long-standing rule of thumb that the gage increment should divide the tolerance into at least ten steps. It limits rounding effects and helps the measurement system see variation. Some applications accept less with justification.
Is resolution the same as accuracy?
No. Resolution is the smallest increment shown. Accuracy, bias and repeatability describe how close and consistent readings are. A gage can display many digits and still be inaccurate.
What if ndc is under 5?
The system may be too noisy for process control. Investigate repeatability and reproducibility, improve fixturing or training, or choose a better instrument. Re-run the study after changes.
Which standard deviations do I use?
Use the part variation and the gage R&R standard deviations from your study output, not the multiplied study variation figures. If you only have the percent columns, calculate from the raw figures if possible.
Netray can help bring gage study results from your ERP and quality system into one view, privately hosted.
Related Tools
Measurement System Analysis Plan Template
Plan MSA for a part or control plan: which measurement systems, which studies, acceptance criteria, owners and due dates.
Quality & InspectionGage Bias and Linearity Study Worksheet
Record reference values and average readings across the operating range and see bias at each point as a share of tolerance.
Quality & InspectionGage Stability Study Control Chart Worksheet
Log repeated master readings over time and get subgroup means, ranges and X-bar and R control limits for a stability check.
Quality & InspectionCalibration Vendor Scorecard Worksheet
Score calibration labs 1 to 5 on accreditation, scope, uncertainty, turnaround and cost and get a weighted total.
More Quality & Inspection tools
See all- A3 Problem Solving Report Template
- Rolled Throughput Yield Calculator
- A3 Problem Solving Template
- Rolled Throughput Yield Calculator
- Cpk Confidence Interval and Sample Size Calculator
- X-bar and S Control Chart Limits Calculator
- Individuals and Moving Range (I-MR) Chart Limits Calculator
- Expected PPM Out of Specification Calculator
- Taguchi Loss Function Calculator