ISO 13849-1 Performance Level (PL) and SIL Reference Table

Machine safety functions such as emergency stop, light curtain muting and guard interlocks are rated with a performance level (PL) from ISO 13849-1, or a SIL from IEC 62061. This table collects the bands you keep looking up in one searchable place.

Download:
ItemGroupRange or definitionNote
PL a
Performance level
PFHd 1E-5 to below 1E-4 per hour
Lowest level; no direct SIL equivalent
PL b
Performance level
PFHd 3E-6 to below 1E-5 per hour
Roughly SIL 1 band at the upper end
PL c
Performance level
PFHd 1E-6 to below 3E-6 per hour
Corresponds to SIL 1
PL d
Performance level
PFHd 1E-7 to below 1E-6 per hour
Corresponds to SIL 2
PL e
Performance level
PFHd 1E-8 to below 1E-7 per hour
Corresponds to SIL 3
SIL 1
Safety integrity level (IEC 62061)
PFH 1E-6 to below 1E-5 per hour
High demand or continuous mode
SIL 2
Safety integrity level (IEC 62061)
PFH 1E-7 to below 1E-6 per hour
High demand or continuous mode
SIL 3
Safety integrity level (IEC 62061)
PFH 1E-8 to below 1E-7 per hour
High demand or continuous mode
Category B
Structure category
Basic safety principles, single channel, no diagnostics
A fault can cause loss of the safety function
Category 1
Structure category
Single channel using well-tried components and principles
Higher MTTFd than Category B
Category 2
Structure category
Single channel with periodic testing of the safety function
Test interval must be sufficiently frequent versus demand rate
Category 3
Structure category
Redundant, single fault does not lose the safety function
Single faults detected where reasonably practicable
Category 4
Structure category
Redundant, single fault detected at or before next demand
Accumulation of undetected faults must not lose the function
MTTFd low
MTTFd per channel
3 years to below 10 years
Mean time to dangerous failure
MTTFd medium
MTTFd per channel
10 years to below 30 years
MTTFd high
MTTFd per channel
30 years to 100 years
Value capped at 100 years per channel
DC none
Diagnostic coverage
Below 60 percent
DC low
Diagnostic coverage
60 percent to below 90 percent
DC medium
Diagnostic coverage
90 percent to below 99 percent
DC high
Diagnostic coverage
99 percent or higher
CCF
Common cause failure
Score of at least 65 out of 100 required
Applies to redundant categories 2, 3 and 4 via the measures list in the standard

Summary table for orientation, not a substitute for the standard. PFHd is the probability of dangerous failure per hour. SIL values use IEC 62061 and IEC 61508 bands. Actual PL determination uses the Table 7 style combination of category, MTTFd and DC, plus software, systematic failure and validation requirements. Verify against the current edition of ISO 13849-1 and ISO 13849-2.

Link safety ratings to serial numbers

Optional: a review of how to hold safety function data against machine serial numbers in your ERP.

Optional. The tool and every export work without this. No spam.

How to use this table

Start from the required performance level (PLr) set during risk assessment, then check that the designed safety function reaches it. Find PLr in the first rows, check the PFHd limit, and confirm the category, MTTFd and diagnostic coverage rows you used in your calculation. If your customer or notified body quotes SIL, use the SIL rows for the equivalent band.

  • Set PLr from risk assessment first
  • Pick a category that can support the PL
  • Check MTTFd and DC band per channel
  • Confirm common cause failure measures for redundant designs

PL versus SIL

PL c, d and e line up with SIL 1, 2 and 3 on PFHd. PL a and b have no clean SIL counterpart. The two methods differ in how they build up the number: ISO 13849-1 uses a simplified category-based method, while IEC 62061 uses a subsystem and reliability block approach. Use the one your harmonised standard or customer references, and state it in the technical file.

Worked example

A safety door with a coded magnetic switch pair and a safety relay is assessed at PLr d. A two channel Category 3 architecture with medium MTTFd (say 20 years per channel) and high DC can reach PL d. If you use a single channel Category 2 design, you would likely fall short. Record each component's B10d value from datasheets when computing MTTFd.

Common mistakes

Treating the category as the PL is the most frequent error. Category is only one input. Another is ignoring validation: ISO 13849-2 expects fault lists and tests. Teams also forget that the PFHd of the safety function is the total of sensor, logic and actuator, not just the safety relay certificate value.

Frequently Asked Questions

What PFHd does PL d need?

PL d requires a PFHd of at least 1E-7 and below 1E-6 per hour. That is the same band as SIL 2 for high demand or continuous mode, though the two methods calculate the value differently.

Is Category 3 the same as PL d?

No. Category 3 is an architecture, and with suitable MTTFd and diagnostic coverage it can achieve PL d, and in some cases PL e is not reachable. The PL depends on category, MTTFd, DC and CCF together.

What is B10d used for?

B10d is the number of cycles at which 10 percent of components fail dangerously. Combined with your operations per year, it gives MTTFd for electromechanical parts such as contactors and valves.

Does the Machinery Regulation change this?

Regulation (EU) 2023/1230 replaces the Machinery Directive from January 2027 and adds items such as software and AI related safety aspects, but the core ISO 13849-1 method remains the common route to presumption of conformity. Check the harmonised standards list.

If you store safety function ratings in spreadsheets and want them linked to machine serial numbers and the technical file in your ERP, we can scope that connection.